Start with the current position
Keep the standards working. Keep the records current.
All rental properties must comply with the Healthy Homes Standards from 1 July 2025, unless an exemption applies. The five standards cover heating, insulation, ventilation, moisture ingress and drainage, and draught stopping.
Once a property meets the standards, the required installations must stay in good working order. Repair them, or replace them when maintenance cannot keep them working. The useful question now is what has changed at the property and whether the evidence still reflects it.
Official guidance:
Tenancy Services — landlord responsibilities
and keeping your property up to standard.
The overview
Five standards at a glance
Use the overview to find a question, then read the detail before making a decision. The checks and records below help organise evidence; they are not a property-specific pass or fail assessment.
| Standard | Practical requirement | Useful evidence | Next question |
|---|---|---|---|
| 01 · Heating | Fixed, acceptable heating that directly heats the main living room and meets its required capacity. | Capacity calculation, heater model and installation records. | Does the calculation match the room and the heater that is there now? |
| 02 · Insulation | Ceiling and underfloor insulation where required, with the applicable R value or thickness and reasonable condition. | Product details, installation date, condition notes and relevant exemption evidence. | Is the insulation still dry, continuous and in reasonable condition? |
| 03 · Ventilation | Openable area in habitable rooms and kitchen/bathroom extraction to outside, with relevant exceptions and qualifying system routes. | Openable-area measurements, fan specifications and discharge route. | Where does the extracted air actually go? |
| 04 · Moisture ingress and drainage | Efficient drainage to an appropriate outfall and an enclosed-subfloor ground moisture barrier where required and possible. | Drainage condition, barrier product and installation records. | Is water leaving the property effectively, and is the barrier intact? |
| 05 · Draught stopping | No unreasonable gaps or holes causing noticeable draughts; appropriate treatment of open fireplaces. | Repair notes, photographs and any written fireplace agreement. | Have weather, damage or recent works opened new gaps? |
From requirement to a useful check
Check each standard
Start with what you can safely observe. Use the linked official guidance for the detailed rules and exceptions.
Heating
Match the heater to the main living room.

What to check
One or more fixed, acceptable heaters must directly heat the main living room. A qualifying heater must be at least 1.5 kW and meet the required minimum heating capacity. Heat pumps and electric heaters need thermostats. Open fires and unflued combustion heaters are not acceptable.
A resistance electric heater is normally unsuitable when the required capacity exceeds 2.4 kW. Qualified existing-heater top-up and other exceptions have specific rules; use the official guidance rather than assuming any portable heater or heat pump is enough.
The 18 °C figure is the calculation basis for the main living room. It is not a guarantee that every room will always be at that temperature. Start with the official Heating Assessment Tool. The regulatory formula and a regulation 10A specialist assessment are distinct pathways with specific criteria and records; an arbitrary calculator or professional opinion is not an equivalent substitute.
A newer formula may apply to qualifying modern dwellings, specified apartments or homes upgraded to the required insulation and glazing criteria throughout. Check the complete eligibility rules and record the calculation pathway.
Evidence to keep
Tool report or applicable calculation; calculation inputs and pathway; heater model/kW; fixed installation, thermostat and installer details; invoices and current photographs.
Weak points and when to get help
Recheck after room or heater changes. Get qualified advice for complex layouts, uncertain inputs, capacity or suitability, apartment/common-property constraints and specialist calculation routes. EWG tools are not compliance calculators.
Tenancy Services — heating standard · Calculating heating capacity
Insulation
Check the product, coverage and condition.

What to check
Ceiling and underfloor insulation is required where applicable. For the three-zone Healthy Homes minimums, ceiling insulation is R 2.9 in zones 1 and 2 and R 3.3 in zone 3; underfloor insulation is R 1.3.
For existing ceiling insulation installed before 1 July 2016, the general thickness route is at least 120 mm, unless there is evidence that it met the relevant R value when installed and has not lost more than 30% of its thickness. Insulation must also be in reasonable condition: look for dampness, mould, damage, compression and gaps.
The three-zone summary does not replace current Building Code requirements for consented work. Official guidance distinguishes building consent before 3 November 2022 from newer consented buildings or renovations. Check which requirements apply to the work.
Evidence to keep
Product labels/R values, installation date, installer statement, coverage and thickness notes, dated photographs or inspection records, and evidence for any specific exemption.
Weak points and when to get help
Old photographs and the mere presence of insulation do not show its current condition. Seek appropriate help for missing labels, restricted or unsafe access, skillion roofs, limited cavities, asbestos/foil risks or uncertain exemptions. Use the official exemption guidance and property records to check whether a limited-roof-space exemption applies.
Ventilation
Follow the air all the way outside.

What to check
Habitable rooms need an openable window, door or skylight to outside that can be fixed open. Its openable area must be at least 5% of the room’s floor area, unless a relevant exemption applies.
Kitchens and bathrooms need extraction to outside or a qualifying continuous mechanical ventilation system. For extractor fans installed after 1 July 2019, kitchens need a fan and ducting diameter of at least 150 mm or exhaust capacity of at least 50 L/s; bathrooms need at least 120 mm or 25 L/s.
Older, working fans that extract outdoors have a separate route. Qualifying continuous systems also have specific design and installation criteria. Neither an older fan nor any whole-home ventilation system automatically proves compliance; check the applicable pathway and exemptions.
Evidence to keep
Room/openable-area measurements, fan type and installation date, written diameter/flow specifications, duct and exterior-discharge photographs, installer details and maintenance records.
Weak points and when to get help
Look for blocked exterior grilles, disconnected ducts, roof-space discharge and recirculating rangehoods mistaken for extraction. Use appropriate installers for new fans, inaccessible ducting and complex or specified systems. For broader moisture, air and comfort questions, see Indoor Environmental Quality.
Moisture ingress and drainage
Remove water. Limit ground moisture.

What to check
Rental properties need efficient drainage for stormwater, surface water and groundwater, including an appropriate outfall. Gutters, downpipes and drains must remove roof water effectively; their presence alone is not enough.
An enclosed subfloor needs a ground moisture barrier where required and possible. The usual polythene-sheet pathway follows NZS 4246:2016. An alternative barrier needs a vapour flow resistance of at least 50 MNs/g and professional installation. These are distinct installation pathways; professional installation is not a blanket requirement for every polythene barrier.
Evidence to keep
Drainage, gutter/downpipe and outfall information; dated condition photographs; barrier product and installation details; relevant inspection, repair and flooding records.
Weak points and when to get help
Look for recurring ponding, blocked or ineffective gutters, persistent damp and missing or damaged barriers. Seek qualified help for drainage design, flooding, uncertain outfalls and unsafe/inaccessible subfloors. Do not enter a hazardous space to obtain a photograph.
Draught stopping
Repair unreasonable gaps safely.

What to check
The property must be free of unreasonable gaps or holes in building elements that cause noticeable draughts. A house’s age or condition is not a reason to leave them. Check doors, windows, floorboards, service and ceiling penetrations, fireplaces and places disturbed by recent trades.
Open fireplaces must be closed off or their chimneys blocked unless the tenant asks in writing for the fireplace to be available and the landlord agrees. This is a specific written-request rule, separate from a tenant’s request for compliance information.
There is no universal maximum door-gap size and no draught-standard-specific exemption. Do not block required ventilation or alter combustion equipment in a way that makes it unsafe.
Evidence to keep
Before/after photographs, repair invoices, maintenance notes and any written fireplace request and agreement.
Weak points and when to get help
Seals can fail after weather damage or repairs. Escalate suspected asbestos, structural movement, complex repairs and consent or safety questions involving fireplaces or wood burners.
Bring the information together
Build an evidence pack
New, renewed or varied tenancy agreements must include a signed statement detailing the property’s current level of Healthy Homes compliance, including relevant exemptions. Keep records showing how the property complies and update them after changes.
The eight topics below are examples to organise, where relevant. They are not a requirement to buy every possible report, and a missing photograph alone does not establish noncompliance. Keep relevant records you hold or acquire, including useful communication and professional advice.
| Evidence topic | Purpose and risk if missing | Possible provider | When to update |
|---|---|---|---|
| 1 · Compliance statement | Records claimed compliance and exemptions. An outdated statement may not match the property. | Landlord, agent or property manager. | New, renewed or varied tenancy; relevant works or changes. |
| 2 · Heating calculation | Shows required main-living-room capacity and the calculation pathway. A heater may exist without evidence of adequacy. | Official tool/regulatory formula records, or the defined qualified-specialist pathway where applicable. | Heater or room changes; relevant calculation inputs or pathway changes. |
| 3 · Heater product and installation | Shows heater type, kW, fixed installation and thermostat. Missing specifications leave suitability unclear. | Installer, supplier and existing landlord records. | Installation, replacement, repair or maintenance. |
| 4 · Insulation condition and performance | Shows coverage, condition and applicable R value/thickness. Old evidence can hide gaps, damage or weak exemption assumptions. | Installer, assessor or safe inspection records. | Re-roofing, repairs, damp events, insulation or access changes. |
| 5 · Fans and outdoor discharge | Shows the applicable extraction pathway, diameter/flow and discharge outdoors. A fan alone does not show compliance. | Electrician, ventilation installer and existing records. | Fan replacement, renovation, duct or grille repair. |
| 6 · Drainage and moisture barrier | Shows water removal, subfloor status and barrier condition. Missing details make moisture issues harder to establish and resolve. | Drainlayer, builder, installer or safe inspection records. | Drainage works, flooding, gutter repairs or subfloor work. |
| 7 · Draught stopping | Shows which gaps were addressed and any fireplace agreement. Recurring gaps become difficult to trace without repair notes. | Landlord, builder or maintenance contractor. | Repairs, weather damage, tenant concerns or fireplace arrangements. |
| 8 · Exemption evidence | Records the specific basis for an exemption. An old assumption may no longer apply. | Property/council records and relevant professional or installer advice. | Consent, access, works, ownership or body-corporate changes. |
Tenancy Services — compliance statement · Receipts and accurate records · Regulation 40 — records
The ongoing routine
After repairs, check again
A heater replacement, fan repair, insulation work, drainage change or fireplace alteration can change the evidence. So can roof/gutter repairs, a damp event or a changed exemption. Keep the record and the property aligned.
- Check the changed installation
Confirm it works, the specification remains suitable and associated work has not created new problems.
- Record what changed
Keep relevant dates, product/installer details, advice, invoices and safe photographs.
- Reconcile the statement
Check whether compliance information, calculations or exemptions need to be updated.
Arrange repairs within a reasonable timeframe for the circumstances; there is no single fixed repair deadline in this guide. Do not treat this routine as a universal annual certification requirement.
Choose the appropriate next step
Where EWG fits
Use EWG’s guidance for first-step clarity: organise what is known, identify missing information, and prepare better questions for official sources or qualified trades. Property managers can use the same structure to organise questions across a portfolio.
EWG does not provide formal Healthy Homes certification, legal advice, engineering sign-off, building inspection, council advice or a Tenancy Tribunal determination. This guide does not establish that a particular property complies.
Contact EWG to discuss what help is available and agree its scope, responsibilities, timing and any cost before proceeding.
Contact EWG to clarify scopeUse qualified help when the question needs it
Refer formal or specialist matters to the appropriate professional: heating/ventilation design, electrical work, gasfitting, drainlaying, building consent, asbestos, structural safety, unsafe access and legal or tenancy disputes.
Looking at everyday comfort?
Explore Healthy Living Home for broader living-condition checks and Indoor Environmental Quality for air, moisture and room conditions. Start with the Healthy Homes hub or Healthy Homes NZ for the wider rental pathway.
For warmth, controls or energy-use questions, ask EWG which Home guidance or support is appropriate. Clarify the scope separately; these routes do not replace a Healthy Homes compliance assessment.
Common questions
Healthy Homes Standards Q&A
Select a question to read the answer.
Does EWG certify Healthy Homes compliance?
No. EWG provides information and decision support for readiness, evidence organisation, issue triage and first-step clarity. It does not certify compliance or replace official guidance or a qualified professional.
Does every rental need to comply now?
All rental properties must comply from 1 July 2025 unless an exemption applies. Required installations must remain in good working order. Check the property’s current position rather than treating the deadline as the end of the task.
What if a property has an exemption?
Record the specific exemption, why it applies and whether it remains current. General and standard-specific exemptions differ. Do not assume an old house, apartment or restricted cavity is exempt; use current official guidance and relevant property evidence.
Does a heat pump automatically mean compliance?
No. It must be fixed, directly heat the main living room and meet the required capacity and applicable heater requirements. Keep the calculation pathway, inputs and heater/installation details; the presence of a heat pump alone is not proof.
What records should be kept?
Keep relevant records you hold or acquire showing compliance: the signed statement, calculations, product and installer details, photographs, invoices, fan specifications, insulation evidence, professional advice, maintenance notes, exemption evidence and relevant communications. The evidence-pack topics are examples to organise where relevant, not a requirement to purchase every report.
What should be checked after repairs or upgrades?
Check that the changed installation works and remains suitable, and that the compliance statement and evidence folder still match the property. Update relevant specifications, calculations, photographs, invoices, advice and exemptions after changes.
When should a landlord use a qualified professional?
Use the appropriate qualified professional for specialist heating or ventilation design, electrical work, gasfitting, drainlaying, building consent, unsafe access, asbestos, structural issues or legal/compliance uncertainty. Do not enter hazardous spaces or alter safety-critical equipment to complete a checklist.
Go to the source
Official sources and review date
Sources checked . This is an information guide, not an exhaustive legal test. Use the current official rules and property-specific evidence when making a compliance decision. All external source links open in a new tab.
- Tenancy Services — landlord responsibilities and compliance information
- Tenancy Services — keeping your property up to standard
- Tenancy Services — heating standard and calculating heating capacity
- Tenancy Services — insulation standard
- Tenancy Services — ventilation standard
- Tenancy Services — moisture ingress and drainage standard
- Tenancy Services — draught stopping standard
- Tenancy Services — compliance statement, records and exemptions
- Government housing policy — Healthy Homes Standards and the 2025 update, announced 29 August and effective 25 September 2025
- New Zealand Legislation — regulation 40, records