01 · Daylight building explorer
LED lighting cost calculator
Use this LED lighting cost calculator to explore workplace energy use, running costs and simple payback. Compare existing lighting, LED fittings and controls using illustrative inputs.
Time of day (visual only)
12:00 pm – typical daytime operation
Operating hours
Office ·
Controls (occupancy & daylight)
Select a zone · illustration onlyOffice · 8 fittings
Adjust the fittings, power and annual hours for this zone.
Fitting type and quantity
Power per fitting
Light-output details needed
Watts measure electricity use; lumens measure light output. We estimate LED power for similar lumens. Light coverage and suitability still need checking.
Complete-fitting watts include the driver or ballast. The artwork does not establish lighting performance.
Results dashboard
Compare lighting options, then explore the numbers.
Synthetic example · NZD excluding GST
Annual energy comparison
Common scale from zero · entered lighting loads only
kWh/year · all four zones
Scroll the chart to view all four options.
Selected result
LED + controlsLighting energy comparison
Compared with existing lighting
How this is calculated
Annual energy = complete-fitting watts × on-hours, plus off-state and separate loads.
Illustrative payback example
Selected scenario · illustrative inputs

Cumulative net benefit (NZ$)
Scroll the chart to explore the full period.
Payback period
—How to use the LED lighting cost calculator
LED lighting cost calculator: 4 options
The LED lighting cost calculator compares existing lighting, LED only, controls only, and LED with controls. Begin with the labelled example to learn how the tool works. The warehouse, office, workshop and loading bay represent separate zones, so their fitting quantities and operating schedules can differ.
Select a zone in the building illustration, then adjust its fitting count, complete-fitting watts and annual lights-on hours. Changes apply to that zone unless you choose to copy its schedule to all zones. The time-of-day slider changes the illustration only; it does not change the annual calculation.
Check power and light output
Enter electrical input for the whole fitting, including its driver or ballast. Lamp wattage alone can miss associated equipment. In illustrative mode, the calculator estimates LED watts from entered light-output efficiencies. These efficiencies are assumptions rather than a product recommendation.
The fitting tool also lets you inspect example references or enter your own documented watts and lumens. Equal lumens do not establish equal illumination at a desk or work surface. Distribution, glare, colour quality, emergency lighting, controls compatibility and installation suitability need separate review. Keep safety and useful lighting service as requirements when comparing options.
A worked electricity example
The opening illustrative example has 50 fittings in total, each using 107 W for 3,000 hours per year. With no additional off-state or shared loads, annual electricity is 50 × 107 × 3,000 ÷ 1,000 = 16,050 kWh. At NZ$0.30/kWh excluding GST, that is NZ$4,815 per year for electricity.
If assumed controls reduce lights-on hours by 20%, the same fittings operate for 2,400 hours and use 12,840 kWh per year. This is an example of the calculation, not a predicted saving for a real building. Existing occupancy or daylight controls must already be reflected in your baseline hours. Add relevant standby and shared equipment separately; the model counts shared loads once.
Read running costs and payback
Use Assumptions and Project costs to review the electricity price, comparison period, installed costs, annual maintenance and recurring controls fees. Keep all costs on a consistent GST basis. The tool provides a GST selector; refer to IRD guidance on calculating GST when checking your figures.
Annual net benefit combines electricity and maintenance differences and subtracts additional recurring fees. Conditional simple payback compares extra upfront cost with positive annual net benefit. Equal or more expensive options can have no useful payback. The cumulative chart uses constant, undiscounted amounts; it does not include financing, escalation, demand charges, HVAC effects or a complete lifecycle forecast.
Compare and keep your assumptions
Capture a scenario before changing its inputs, then restore it when comparing alternatives. View report summarises the current model, while Export CSV provides the underlying inputs and results. Review the assumptions and any unavailable values alongside the headline totals. A blank or invalid input is not evidence of zero consumption or zero cost.
Changes and captured cases remain in the current tab’s memory. Closing or reloading the tab can lose them, so use the deliberate report and CSV exports when you want a record. Use synthetic or redacted examples during EWG’s current development stage.
Use the comparison as a first step
This tool supports learning and an initial comparison. It does not establish a lighting design, installation specification, quote or guaranteed saving. Before an actual project, check site conditions, equipment records, operating schedules, tariffs and supplier proposals with suitably qualified specialists.
For other equipment comparisons, explore the EWG energy cost calculators. To discuss an initial advisory review and its separately agreed scope, price and timing, contact Eco Wave Green.