EWG
Choose a business example

Each business has its own editable electricity and solar example; your changes are kept when switching.

Explore your working day

NASA POWER weather · 2015–2024

Operating patternDaytime
January · weekday · 12:00Illustrative flow, not live metering
Illustrative industrial workshop with workbenches, timber storage and a service yard. Bare roof; solar panels and calculated flows are separate overlays.
Solar supplying the site——
Exported to the grid——
Imported from the grid——
40 kWp
0 kWp300 kWp
Exact entry
50 kWmaximum
Exact entry

Swipe or scroll sideways to explore the whole scene. Keyboard: focus the scene and use the arrow keys.

Illustrative workshop · synthetic operating day
—12:00—
00:0006:0012:0018:0023:30

Annual energy · first modelled year

kWh or MWh over the full year · separate from the scene’s kW
Total site demand—
Actual solar generated—
Useful solar to demand——
Exported to grid—
Grid imports remaining—
Curtailed available AC—Lost potential shown separately

Compare the same business

Comparison basis

Four scenarios share the same service demand and assumptions. The battery column keeps the original timing. Combined shifting and storage appears separately when selected. Money covers supported components only, in NZD excluding GST, pre-tax.

Initial capital
Unavailable
Grid purchases / year
Unavailable
Charge reduction / year
Unavailable
Operating benefit / year
Unavailable
Project NPV
Unavailable
Maintained recovery
Unavailable
Configuration & availability

Current calculation pending.

Initial capital
Unavailable
Grid purchases / year
Unavailable
Charge reduction / year
Unavailable
Operating benefit / year
Unavailable
Project NPV
Unavailable
Maintained recovery
Unavailable
Configuration & availability

Current calculation pending.

Initial capital
Unavailable
Grid purchases / year
Unavailable
Charge reduction / year
Unavailable
Operating benefit / year
Unavailable
Project NPV
Unavailable
Maintained recovery
Unavailable
Configuration & availability

Current calculation pending.

Initial capital
Unavailable
Grid purchases / year
Unavailable
Charge reduction / year
Unavailable
Operating benefit / year
Unavailable
Project NPV
Unavailable
Maintained recovery
Unavailable
Configuration & availability

Current calculation pending.

Same shifted service demand; the battery addition remains a separate comparison.
Detailed comparison table and availability
Current comparison pending.

Business rhythm

Adjust annual service demand and when the business operates. Results update automatically.

Operating patternChanges the annual load profile
90 MWh
0 MWh1,000 MWh / year
Operating days
07:00
00:0023:30
10 hours
0.5 hours24 hours
15%
0%80%
Historical weather years · annual comparison, calendar and peaks

Day-class charts show ten-year means. Choose a date in the annual calendar or inspect a dated monthly peak for an individual year. Demand-charge estimates use hourly-smoothed solar.

Annual business calendar and background load

Select dates when shifts may start. Day-preview buttons only change the view. Fewer starts redistribute the same selected annual service demand; they do not imply efficiency or reduced production.

Permitted shift-start weekdays

Derived annual background share pending.

Each historical year uses its real weekdays and leap days in fixed NZST. Closures prevent shift starts. Overnight work can carry into the next date, including New Year. Background continues during closures.

Explore historical dates and business demand

Each tile shows daily demand from the chronological calculation. Select a date to inspect its power and storage; annual assumptions stay unchanged.

Operating hours notes

Working hours are the total across shifts that start on the same operating day, including work after midnight.

Current hours08:00–17:00 on operating days
How shifting works

Only move tasks that your operation can safely reschedule.

Battery settings and comparison

Compare with the same panels, operating schedule and flexible-work setting.

Battery on this day

Additional installed cost—Capacity-based example cost
Extra annual bill reduction——
Additional project NPV——

Solar surplus charges the battery; stored solar then meets later demand. Power limits, reserve, losses and replacements are included. The original fictional example uses NZ$50,000 installed and NZ$30,000 replacement costs. Capacity changes keep entered costs constant; edit them separately. Fixed capacity is an illustration, not a lifetime-performance claim. This dispatch is not a peak-shaving optimiser or an outage-backup design.

System budget & allowances

NZD excluding GST. The example PV cost follows panel size; a fixed amount you enter stays fixed.

PV equipment

Unavailable

Record

Allowance pending.

Battery equipment

Unavailable

Record

Allowance pending.

Results & analysis

Illustrative operating day

kW

—

Solar contribution

annual

Two different questions about the same energy.

Project cashflow

net NZD

Purchase, operating costs, replacements and end-of-life costs.

Which interval sets the billed peak?

Current peak unavailable.

Grid-only baseline

Selected scenario

The inspected day uses the selected historical year, regional weather and fictional demand. The model estimates half-hour peaks using hourly-smoothed solar.

Annual performance by month

Highest baseline import interval—Highest post-solar import interval—Annual demand-charge reduction—

Demand charges use each month’s maximum imported kW in the selected billing window. A lower daytime import does not guarantee a lower billing peak.

Year-one bill reduction

Imported energy charges
—
Export credits
—
Demand-charge saving
—
Fixed-charge saving
—
Supported charge reduction—
Charge comparison basis—

Annual operating costs

—

Annual upkeep allowance.

Year-one operating benefit—Before one-off costs, financing and tax

Grid-purchase change

—

Compared with grid only for the same service.

Explore financial outcomes

Base inputs, as entered.

Financial basis

NZD excl. GST · cash purchase · pre-tax. Full GST recovery assumed.

Sensitivity scenarios, not probability forecasts.

Project evidence and boundaries

Demand profileFictional demandRoof / structureTo assessExport approvalUnconfirmedFundingUnconfirmed
Evidence & physical boundaries

—

Current assessment prioritiesConfirm demand timing, tariff evidence and export permission.

Calculator details

Applicability & comparison boundary

No identifiers or records are needed. Demand is fictional. Regional NASA weather drives the PV model. This does not model existing assets, multi-meter allocation, partial GST, tax, PPA/lease or tariff ratchets.

Tariff & demand charges

Supported billing components

All rates below are editable fictional assumptions, excluding GST. Results cover supported charge components only, not a verified complete bill. Negative import/export prices are supported.

Monthly maximum demand

The peak window uses the start/end hours and weekday rule above, including when the energy tariff is flat. kVA, reactive charges, ratchets, minimum demand, tiers and complex contracts are outside this model.

Baseline supported charges—
Remaining energy charges—
Remaining demand charges—
Fixed charges—
Less export credits—
Scenario supported charges—

A synthetic baseline is reconstructed here. No actual bill has been reconciled. A material unsupported charge requires a detailed assessment.

Ownership, costs & finance

Cashflow and occupancy period

Default cost is a fictional NZ$1,375 per kWp allowance. Quotes and exclusions are unconfirmed. Full GST recovery is assumed; GST payment/refund timing, income tax, grants, PPA and lease contracts are not calculated. No residual value or tenancy renewal is assumed.

What could change this result?

Compare one trial assumption with the current scenario. The sunlight multiplier scales GHI, DNI and DHI before PV conversion. Differences are Trial minus Current.

Trial values update automatically.

Decision report · current comparison

No current report. Complete the current calculation before interpreting results.

Financial cases & capital ratio

Conservative and upside cases vary all three radiation components before conversion and adjust initial capital. The historical range separately describes variation across the ten weather years.

Open to calculate current case previews.

Capital / year-one operating benefit is unavailable.

The simple ratio assumes year-one operating benefit repeats. It omits timing, degradation and later costs, and is not first or maintained cashflow recovery.

EWG / Solar Power Calculator

A clearer first look at your operating choices.

EWG Solar Power Calculator — commercial solar summary

Application build 6.0.0 · model EWG-COMMERCIAL-NASA-6.0.0.

Calculation unavailable. No current numerical result. JavaScript must complete before results can be printed. Review demand timing, export permission, tariffs, costs and the model assumptions before any real decision.

Calculator details

Operating day data & details

No current data.

Mean historical half-hour profile · select a time on the chart.

Solar contribution data & details

No current data.

—

Project cashflow data & details

No current data.

—

Peak-day plotted data · kW

No current peak-day data.

Monthly energy and billed peaks

No current data.

Site & model assumptions

Evidence, production and methods

Workshops & Manufacturing

Physical inputs and unknowns

All starting values are the selected fictional example. Clear a field for unknown. Use its “Use example” button to explicitly restore an example value. Edits remain synthetic assumptions, not measured evidence. The sliders and these fields control the same inputs. Software ranges are not engineering limits.

Transparent screening prototype

One fictional site and one assumed billing boundary. Business artwork is illustrative; it does not establish floor area, roof suitability or electricity demand. No real customer uploads or address lookup.

—

Battery assumptions

AC-coupled, surplus-solar-only dispatch. No grid charging, tariff optimisation, battery exports or outage backup.

Decline starts in year 2, compounded once each year. Reserve remains the entered fraction of that year’s available capacity; power and efficiency stay fixed. Replacement is paid at the end of every replacement-interval year, including the horizon year; the next year starts at original capacity. Each year has its own repeating-year SOC, with no net initial-energy benefit. No continuous ageing, cycle/temperature ageing, standby consumption or replacement downtime is modelled.

Emissions method

The business examples share the 2025 NZ annual grid-average factor. The comparison multiplies the change in gross grid purchases by the dated factor. Regional weather drives half-hour energy flows and still uses the annual factor.

To use a different factor or year, enter its public source. Changing the preset factor or year clears the example source.

Ministry for the Environment, Measuring Emissions Catalogue 2026, Table 5.2. The example uses purchased electricity only. Export credits, transmission and distribution losses, and lifecycle effects are outside this estimate. A factor, applicable year and public source are all required; EWG has not authenticated entered provenance. No carbon revenue is included.

Business electricity examples

The starting sizes and operating hours are illustrative choices. Annual electricity estimates use the references below, rounded for editable examples. They cover electricity only, excluding gas and other fuels; they are not current NZ business averages or measured demand profiles. The artwork does not determine the assumed size.

  • Office: 600 m² × 115 kWh/m²/year = 69,000, rounded to 70,000 kWh/year.
  • Light workshop: 800 m² × 110 = 88,000, rounded to 90,000 kWh/year. Heavy industrial processes are excluded.
  • Food retail with substantial refrigeration: 600 m² × 428 = 256,800, rounded to 260,000 kWh/year.
  • Hospitality and accommodation: 600 m² × 273 = 163,800, rounded to 165,000 kWh/year. This broad category does not establish the exact restaurant/accommodation split.
  • Dry warehouse with a small supporting office: 1,200 m² × 35 = 42,000 kWh/year. Refrigeration and major processing are excluded; distribution centres have a different benchmark.
  • Schools & Childcare retains the fictional 60,000 kWh/year term-time example, with four three-week closures. This is not a typical school or an official term calendar.

The first four references are historical premises electricity medians in BRANZ BEES (2014), Tables 18–20. The warehouse reference comes from the NZ rows in the NZGBC 15B calculator (2024); its warehouse guidance explains the covered activities. A benchmark is not a forecast for your premises.

Operating hours describe main activity, not a complete overnight shutdown. Background demand continues, including refrigeration and accommodation. The existing synthetic office, workshop and refrigeration shapes are retained; hospitality reuses the existing retail service shape, and dry warehousing reuses the existing workshop shape. Their overnight weights and monthly variation are illustrative, not derived from these annual benchmarks. The existing 15% flexible-work example remains editable for these five businesses; the school starts at zero. The five new examples have no additional closure dates. Solar equipment and cost assumptions are described below.

Solar starting examples

Offices start at 30 kWp DC with a 25 kW AC inverter; workshops at 40/35; food retail at 100/90; hospitality at 65/55; dry warehouses at 20/20; and schools at 20/20. These are editable fictional configurations, not equipment selections or recommended sizes for actual premises.

Starting plant sizes and costs are fictional commercial examples inherited from build 5.2.43. Location and panel settings determine the current NASA-based generation.

Inverter examples are rounded near the previous 70/80 AC/DC ratio; no commercial equipment model is selected. Installed allowances use the existing fictional NZ$1,375/kWp excluding GST. Upkeep, non-battery replacement, removal and other cost assumptions remain separate and editable. Battery examples are described below. Roof, connection and export constraints remain unconfirmed. EECA’s commercial solar guidance explains why actual sizing requires detailed consumption and generation analysis; it does not prescribe these example capacities.

Switching businesses restores that business’s edited demand, panel capacity, inverter capacity and installed allowance, together with its battery settings described below. Editing demand does not automatically change the solar system. “Use example” restores the selected business’s starting value for that field. By default the fictional installed allowance follows DC capacity at NZ$1,375/kWp excluding GST. Enter a fixed amount to keep it unchanged as capacity changes, or choose “Use size-based PV cost” to restore the link. The panels shown on the roof illustrate relative capacity only.

Battery starting examples

Each business has its own storage example, stated as capacity before reserve / charge and discharge power: offices 30 kWh / 15 kW; workshops 40 / 20; food retail 100 / 50; hospitality 60 / 30; dry warehouses 15 / 10; and schools 20 / 10. These are editable illustrations, not equipment selections or optimal sizes.

The examples were checked against the existing half-hour solar-surplus and electricity-demand patterns. Continuous refrigeration and evening hospitality give different opportunities from weekday workplaces and term-time schools. A year’s total surplus cannot establish how much a battery can store and deliver on a particular day. The model only charges from surplus solar and supplies later site demand; it does not model grid charging, tariff trading or outage backup.

The starting 20% reserve leaves 24, 32, 80, 48, 12 and 16 kWh respectively above reserve, before conversion losses. The existing 90% round-trip efficiency, replacement interval and lifetime-capacity assumptions remain editable. kWh measures storage capacity; kW limits how quickly it charges and discharges. No battery product or backup duration is implied.

The old 100 kWh example carried NZ$50,000 installed and NZ$30,000 replacement allowances. These fictional amounts are now scaled at NZ$500/kWh installed and NZ$300/kWh replacement, excluding GST. They are not current market quotes. Other upkeep and non-battery costs remain separate editable assumptions. The EECA commercial solar guidance describes battery uses and the need for site-specific advice; it does not prescribe these example capacities or costs.

Switching businesses restores its edited battery capacity, power and installed/replacement allowances, with the corresponding allowance record. “Use example” restores that business’s value for the selected field. Later edits to demand, solar capacity or weather do not automatically resize or reprice the battery. Review the battery and its costs together when changing the example.

How the model works

Location selects NASA POWER weather for the entire comparison. The inputs and source are recorded in the report.

  • Business demand uses actual Gregorian weekdays and 48 fixed-NZST slots per day. Each slot in an hour receives half that hour’s PV energy.
  • Each business starts with its own annual electricity demand and hours. Switching businesses restores that business’s edited settings. Changing its calendar or timing preserves its selected annual demand. Selected operating days are shift-start days. Overnight shifts continue into the following morning; background demand remains when closed. Flexible work moves energy to daylight on its shift-start day.
  • Panel DC capacity, inverter AC rating and export limits are separate. Generation excludes curtailed potential; self-consumption includes useful solar-origin battery discharge after losses.
  • The battery uses an AC-bus, solar-surplus-only rule with repeating-year energy balance. Capacity is either explicitly fixed as an illustration or follows the entered annual decline/reset rule. Efficiency and power stay fixed; lifetime performance is unverified. No grid charging, battery export or backup operation is modelled.
  • Project cashflows include capex once, annual operating costs, recurring inverter/battery replacements, entered roof works and exit/removal cost. Generation declines annually. No residual value is credited.
  • Payback is the first cumulative cashflow recovery. Any later reversal is flagged; the maintained-recovery measure is also shown. NPV discounts all project cashflows at the stated rate.
  • Tenant benefits stop at the shorter of evaluation horizon and secure occupancy. Lending approval, financing fees, tax, contract transfer and GST timing require separate assessment.

Basis: EWG Commercial Solar Calculator Reference v1.0, 22 October 2026. Model 1.0. Roof, metering, phase treatment, network approval and actual contracts remain unconfirmed.

Choose your NZ region

Choose the district to select its NASA POWER reference point.

These 18 weather regions differ from regional council boundaries.

Selected area
Wellington City
Weather region
Wellington · WN
Representative location
Wellington

Choose a city or district. No address is needed.

Regional historical weather, fictional business demand. Hourly sunlight, temperature and wind drive solar output. Business demand remains synthetic. The ten separate years feed hourly PV, half-hour grid flows, monthly charges and project finance.

Illustrative panel setup selected. You can change the settings below.

Panel settings & assumptions

Wellington mainland and the illustrative panel setup are selected initially. Change the location or panel settings to explore another case.

Example: north-facing, 30° tilt, open rack, 14% DC losses, no additional shade, 20% ground reflectance, 96% inverter efficiency and −0.47%/°C temperature coefficient.

Additional shading must exclude any shading already included in combined losses. The sunlight multiplier is a hypothetical resource variation, not an accuracy range.

Weather source & quality
Select a location to see its pinned source.

Area names: Stats NZ – Tatauranga Aotearoa (CC BY 4.0). Mapping: MBIE H1/VM2, second edition. Weather: NASA POWER Hourly API · EWG processed NASA regional data under CC BY 4.0. Data licence

A SCOPED NEXT STEP

Options for an evidenced assessment

An independent assessment is optional. If you choose paid help, agree a bounded scope and budget with a qualified assessor. The business or asset owner is the proposed payer; deliverable, cost basis, funding and payment dates remain to be agreed. If a funded scope is not agreed, retain this educational comparison and defer detailed assessment.

  1. Establish the meter boundary and existing assets through an appropriate professional evidence process.
  2. Validate demand and reconstruct the actual tariff in an approved data workflow.
  3. Commission qualified review of roof, electrical and connection constraints; no self-inspection is requested.
  4. Compare equivalent quotes, operating commitments and a funded delivery route.
This action is a planning checklist. No assessment has been booked, ordered or paid for.

How to use the commercial solar power calculator

This commercial solar power calculator lets New Zealand businesses explore how solar fits their operating hours. Compare grid electricity, solar, load shifting and battery storage using editable, fictional examples. The results are a starting point for investigation, not a quote, measured demand forecast or site recommendation.

1. Choose your business and district

Choose one of the six illustrated business examples, then select your district. The same ten historical weather years feed the energy, billing and project comparisons.

Workshop illustration used to choose a business in the commercial solar power calculator
Choose a starting exampleReplace its fictional demand, operating pattern and equipment assumptions with evidence for your own premises.
Business rhythm illustration for operating hours and daily electricity demand
Check when electricity is usedSolar value depends on timing as well as the annual electricity total.

2. Set demand and your working day

Under Business rhythm, enter annual electricity use and choose daytime, two shifts, 24-hour or night-shift operation. Adjust operating days, start time and working hours. The calendar controls cover weekends, shutdown periods and background demand. Use the time slider and seasons to inspect the illustrative operating day. Scene values are power in kW; annual energy is shown in kWh or MWh. One MWh equals 1,000 kWh.

3. Compare four operating options

Compare Grid only, Solar, Solar + load shifting, and Solar + battery for the same business. Load shifting changes when the flexible share of demand is served; it does not mean that all business electricity can move into daylight. You can also compare shifting and a battery together. Battery capacity, power, efficiency and reserve are separate inputs. Changing one does not prove that equipment is suitable for your premises.

Set panel capacity in kWp, inverter AC rating and the assumed export limit. The export limit is a modelling input, not network permission. Check the battery settings and equipment cost record after changing a scenario. A fixed PV cost you enter remains fixed; the fictional PV allowance otherwise follows panel size.

4. Review tariffs, costs and results

Open Calculator details for flat or time-of-use prices, export credits and monthly demand charges. Enter costs, upkeep, replacements, discount rate and project horizon where applicable. Read the GST display label before comparing money amounts. Inspect the monthly table and peak-day data: a lower daytime grid import does not necessarily reduce the billed monthly peak.

Illustrative savings compare the modelled electricity charges. Year-one operating benefit deducts annual upkeep. Net present value discounts project cash flows, while maintained recovery considers whether recovery lasts through the selected horizon. These measures answer different questions. The calculator’s charts, explanations and decision report identify unavailable results and missing evidence.

Worked example: the default workshop

With the unchanged Workshop example, Solar selected, annual demand of 90,000 kWh, 40 kWp of panels, a 35 kW inverter and the 50 kW export assumption, the model generates about 50.0 MWh in the first year. About 38.2 MWh supplies demand, 11.8 MWh is exported and 51.8 MWh is imported. Solar supplies 42.4% of site demand.

At the example import price of NZ$0.24/kWh and export credit of NZ$0.08/kWh, with no demand charge, the displayed annual savings are NZ$10,108 excluding GST. After NZ$1,500 annual upkeep, year-one operating benefit is NZ$8,608. With the original costs and 20-year assumptions, the model shows NZ$20,528 NPV and 6.5-year maintained recovery. These rounded results apply only to this fictional example; changing inputs changes the outcome.

5. Save, print and gather evidence

Save summary downloads an HTML report that opens in a browser. Print summary and Print full report use the browser’s print controls, where you can also save a PDF. Keep the assumptions and report together when comparing alternatives. Close this guide to return to your current inputs, or use Reset to restore the calculator’s examples.

Before a real investment comparison, gather interval electricity data, tariff and demand-charge schedules, roof and structural information, shading evidence, equipment quotations and network export conditions. Review ownership, funding and assessment boundaries. The calculator does not replace an engineered design or confirm export approval.

For background, read the existing EECA commercial solar guidance. For household scenarios, use the home solar power calculator.